TR-Q8800 Full Automatic Integrated Sulfur Analyzer


Sample feeding: manual
Testing range: 0.01%~10% (expandable according to requirements)
Testing method: Infrared Spectrum Absorption Method
Sample Weight: Coal:300mg±10mg; 
oil: 100mg±10mg
Testing Time: 180s for one sample
Temperature: 1300ºC~1350ºC
Sample number: disposable lofting 12, unlimited additional samples
Power Supply: 220V, 50/60HZ
Power: ≤ 4 KW
Dimension: 670x560x720
Weight: 65KG
     PRODUCT EXHIBITION

     

     PRODUCT INFORMATION 

     Application Area: 
    It is applicable in the industry such as electrical power, coal, commerce inspection, environment protection, metallurgy, papermaking, petrochemical, earth probe, and the research institution or quality inspecting organization to measure the sulfur content in the materials of coal, cinder, coke, catalyst, minerals, rock, and petrochemicals.
     

     

    CHNICAL CHARACTERISTICS

     

    1. Intelligence, automatic sampling, testing, sample, output test results.The institutions directly or has applied for national patent (patent no. : 201320030769.9);

    2. Infrared pool, USES the international advanced level of ultra low drift equipment stability, precision and accuracy of the international first-class;

     3.Low company unique gas concentration dilution design can not replace the infrared pool under the premise of extend measurement range; 

    4.Software fault-tolerant diagnosis, intelligent judgment and prompts fault location;

    5.Using imported heating element and the combustion tube, with long service life;

    6. Imported pneumatic components and the optimization of gas circuit design, guarantee the tightness, without user leak detection;

    7.Low intake pipe and rod directly or separate, long service life, convenient maintenance, simple, low cost;

    8.Unique airtight structure, prevent the sulfur dioxide in air influence the results;

    9.Have the function of waste gas treatment, completely avoid laboratory air pollution;

    10. can display, print, recalculation, save and query results;With the function of statistics, it can help the user to easily obtain the results mean, poor, standard deviation and relative standard deviation, and other important data;