Specification:
Specification R-8074: Three-phase Multifunctional Intelligent Electricity Meter with Transmitting and LCD Display
Measured Channels Three-phase voltage and current, and expansion I/O function
Measured Parameter The real effective value of current and voltage, power factor, active power, reactive power, frequency, power factor, input active electrical degree, output active electrical degree, total electrical degree, reactive electrical degree, apparent power, total apparent power
Input Frequency 45~75Hz
Voltage Range 10~500V, can measure higher voltage by appending voltage transformer and setting voltage transformation ratio
Current Range Basic range is 0~5A, can measure greater current by appending current transformer, and setting current transformation ratio.
Signal Processing 16bits A/D converter,6 channels, every channel synchronistical AC samples at the speed of 4KHz.The real time data of module is real effective value of 1 second( refresh one time a second)
Overload Capability Can measure exactly 1.4 times of range input; instant current (10 cycles) is 5 times, no damage when voltage range is 3 times.
Output Data Electric parameters such as three-phase voltage Ua, Ub, Uc; three-phase current Ia, Ib, Ic; active power P, reactive power Q, power factor PF, frequency f, active power of each phase Pa, Pb, Pc; reactive power of each phase Qa, Qb, Qc; forward active electrical degree, reversed active electrical degree, forward reactive electrical degree, reversed reactive electrical degree.
Output Interface RS-485/RS-232(It is optional,customers need to declare before ordering goods.)
Communication Rate 1200,2400,4800,9600BPS
Communication protocol ASCII commands and MODBUS/ASCII protocol
Degree of Accuracy Current, voltage: 0.2, the rest: 0.5
Parameter Setting Input by film keyboard
Power supply 220VAC
Display LCD liquid crystal display
Built-in real-time clock provides the information of year, month, day, and hour, minute and second, to make sure supplying electricity uninterruptedly for 10 years with lithium cell.
 
Note: R-8074 possesses the functions above, also include optional configuration function (If you need these functions, please communicate with your sales):

Can configure PROFIBUS-DP communication protocol, RS-485 communication port.
Can configure 2~8 channels switch input port, photoelectric coupler isolated input.
Can configure 2~8 channels switch output port, optional relay port or photoelectric coupler port, also can set as electrical degree pulse output.
Can configure 2 channels analog input port, 4~20mA or 0~5V signal input.
Can configure 2 channels analog output port, 4~20mA signal input, also can set as communication remote regulating output or corresponding a certain electricity acquisition parameter output.
 
Performance Specification
Order Item Description Measurement accuracy
(Accuracy range)
1 Voltage of each phase
(V1, V2, V3)
Direct measurement range: 0~500.0V, denote by 16 bits unsigned short integer (Divided by 100). 0.2%
(50~500V)
Voltage transformer PT ratio is 1~10000:1, denote by 16 bits unsigned short integer
Display value: 0~1000.0KV, 6 digits number (1 digit after radix point).
2 Current of each phase
(I1, I2, I3, In)
Direct measurement range: 0~5.000V, denote by 16 bits unsigned short integer (Divided by 1000). 0.2%
(0.5~5A)
Voltage transformer CT ratio is 1~10000:1, denote by 16 bits unsigned short integer
Display value: 0~50.000KA, 5 digits number (3 digit after radix point).
3 Active power of each phase (P1, P2, P3) Direct measurement range: 0~2500.0W, denote by 16 bits signed short integer (Divided by 10). Display value: 0~50000.0MW, 6 digits number (1 digit after radix point).  0.5%
(25~2500W)
(0.5<PF<1)
4 Total active power for three phase (P) Direct measurement range: 0~7500.0W, denote by 32 bits signed long integer (Divided by 10). Display value: 0~150000.0MW, 7 digits number (1 digit after radix point). 0.5%
(75~7500W)
(0.5<PF<1)
5 Reactive power of each phase (Q1, Q2, Q3) Direct measurement range: 0~2500.0VAr, denote by 16 bits signed short integer (Divided by 10). Display value: 0~50000.0MVAr, 6 digits number (1 digit after radix point).  0.5%
(25~2500Var)
(0.5<PF<1)
6 Total reactive power for three phase (Q) Direct measurement range: 0~7500.0Var, denote by 32 bits signed long integer (Divided by 10). Display value: 0~150000.0MVAr, 7 digits number (1 digit after radix point). 0.5%
(75~7500Var)
(0.5<PF<1)
7 Apparent power of each phase (S1, S2, S3) Direct measurement range: 0~2500.0VA, denote by 16 bits signed short integer (Divided by 10). Display value: 0~50000.0MVA, 6 digits number (1 digit after radix point).  0.5%
(25~2500VA)
 
8 Total apparent power for three phase (S) Direct measurement range: 0~7500.0VA, denote by 32 bits signed long integer (Divided by 10). Display value: 0~150000.0MVA, 7 digits number (1 digit after radix point). 0.5%
(75~7500VA)
 
9 Power factor of each phase (PF1, PF2, PF3) Denote by 16 bits signed short integer (Divided by 10000). Display value: -1.000~1.000, 4 digits number (3 digits after radix point).  0.5%
(-0.5~0.5)
 
10 Frequency (f) Direct measurement range: 45~55Hz, denote by 16 bits signed short integer (Divided by 100). Display value: 0~55.0Hz, 3 digits number (1 digit after radix point).  0.2%
(45~55Hz)
(Voltage≥20V)
11 Active electrical degree 
(Input active: Epi)
(Output active: Epo)
Direct measurement range: 0~4000.000KWh, denote by 32 bits unsigned long integer (Divided by 1000).
When the absolute value of any phase's active power is less than 1 (W×PT×CT), this phase will not cumulate active electrical degree.
Display value: 0~4000.000KWh, 7 digits number (3 digits after radix point).
When the input active electricity acquisition reach up to N×0.01KWh×PT×CT, output 1 pulse (50% duty ratio). N is pulse parameter, can be set at the board.
0.5%
(25~2500W)
12 Reactive electrical degree 
(Inductive reactive: Eqind)
(Capacitive reactive: Eqcap)
Direct measurement range: 0~4000.000KVArh, denote by 32 bits unsigned long integer (Divided by 1000).
When the absolute value of any phase's reactive power is less than 1 (W×PT×CT), this phase will not cumulate reactive electrical degree.
Display value: 0~4000.000KVArh, 7 digits number (3 digits after radix point).
0.5%
(25~2500Var)
13 Outside supply AC220V±10%, power consumption≤15W  
14 Environment Temperature: 10~45ºC; Humidity: 0~95% (non-condensing)  
15 Liquid crystal display White characters on blue background, 128×64 resolution, 5 lines Chinese word display.