Timer Relay (CAS1-S Series)

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Zhejiang

  • Validity to:

    Long-term effective

  • Last update:

    2017-10-26 15:27

  • Browse the number:

    36

Send an inquiries

Company Profile

Xinling Electrical Co., Ltd. China

By certification [File Integrity]

Contact:Miss Shuyan Jin(Mr.)  

Email:

Telephone:

Phone:

Area:Zhejiang

Address:Zhejiang

Website: http://clinelectrical.jssytm.com/

Product details
Specification
Panel size Operating 
mode
Setting&display mode Contact Input signal control Installation 
mode
Delay range Model
48×48mm on-delay dial switch 
with digital display
1C time delay reset and pause panel type, device type,
35mm guide rail
0.01s~99990h CAS1-S14HT40
back-panel wiring type CAS1-S14MT40
2C time delay none panel type, device type, 
35mm guide rail
CAS1-S20HT40
back-panel wiring type CAS1-S20MT40
reset and pause panel type, device type, 
35mm guide rail
CAS1-S24HT40
back-panel wiring type CAS1-S24MT40
1C time delay
and 1C
instantaneous
none panel type, device type, 
35mm guide rail
CAS1-S40HT40
back-panel wiring type CAS1-S40MT40
cycling delay 2C time delay none panel type, device type, 
35mm guide rail
0.1s~990h CAS1-RS20HT22
back-panel wiring type CAS1-RS20MT22
1C time delay reset and pause panel type, device type, 
35mm guide rail
CAS1-RS14HT22
back-panel wiring type CAS1-RS14MT22


Rated value

Rated supply voltage AC/DC100V~240V 50Hz; DC24V
Operating voltage fluctuation range 85%~110%
Input mode no voltage input(short circuit.open circuit)
Minimum signal input time 0.1s
Contact capacity 3A AC220V(Resistive)
Ambient temperature  -5ºC~40ºC(no ice)
Ambient humidity If the ambient temperature is 40ºC,the RH≤50%. 
It allows higher relative humidity in a lower temperature. 
For example,when the ambient temperature is 20ºC, the RH≤90%. 
Special measure is needed for occasional condensation produced
by temperature changes 
Altitude ≤2000m





Outline dimension



Operatioin procedure

Note:
Please choose the specific model from the above table when enquiry(e.g.:CAS1-S14HT40) so that we can quote immediately.